13. Technical specifications
Supply voltage
Mains voltage:
Low voltage:
Power consumption
Certifications
Categor�� 3 acc. to EN 954-1
Safet�� device acc. to EN 12978
Terminal resistance of the SCEs
nominal value
upper switching point
lower switching point
Relay stages
Max. switching voltage
Max. switching current
Mechanical life-time
Safety relay switching times
Response time
Turn-off time
Version ISK 74-30
Dimensions (HxWxD)
PCB
Weight
Version ISK 74-31
Housing
Dimensions (HxWxD)
Housing
Housing incl. screw conn. 140 x 122 x 56 mm
Protection class
IP65 with M16 screw fittings
IP54 with M16 blanking plug
Weight
Version ISK 74-33
Dimensions (HxWxD)
Housing
Weight
Temperature range
Connection cable cross-section
single- or fine-stranded cable 0,75-1,5 mm
All voltages connected to the switching unit must be
safely isolated!
20
Relay
U
230 V AC 50/60 Hz
Mains
U
24 V AC/DC ±10 %
24 V AC/DC
E
P
3 VA
max
R
= 8,2 kΩ
nom
R
> 20 kΩ
AO
R
< 2,5 kΩ
AU
240 V ~ / 30 V -
4 A ~ / 4 A -
>10
actuations
6
< 20 ms
500 ms
113 x 100 x mm
285 g
Pol��st��rene with transparent cover
120 x 122 x 56 mm
650 g
122 x 103 x 18 mm
295 g
-20°C to +55°C
2
Version ISK 74-30
Version ISK 74-31
Version ISK 74-33
Certificate no.
78/780/551696
Test report no.
04/YTT/551696