9.5. Commissioning / functional test

The plant / machine must be tested for proper function after all of the electrical connections have
been established and the suppl�� voltage has been turned on.
Actuate the sensors in sequence.
Check the switching units for proper reaction.
The safet�� s��stem must be professionall�� inspected at appropriate intervals. The inspection must
be documented in such a wa�� as to be comprehensible at all times. The requirements of the plant/
machine manufacturer are to be taken into account and followed.

10. Error diagnosis

If the suppl�� voltage is both wired and applied correctl��, the decimal point must switch off c��clicall��
on the display only briefly. If an internal error has occurred, the error message is indicated by the
number of pulses.
LED
LEDs are not illumi-
nated
Decimal point flashes
c��clicall��
Middle horizontal
bar illuminates
At least one vertical
bar illuminates con-
stantl��
At least one vertical
bar flashes
If the error is not in the wiring, the function of the electronics can be tested b�� connecting an
8.2 kW resistor to the respective SCE input on the switching unit.

11. Taking out of service and disposal

The products manufactured b�� ASO are intended solel�� for commercial use (B2B). At the end of use,
the products are to be disposed of according to all local, regional and national regulations. Products
can also be returned to ASO, which will then dispose of them properl��.
30
Error
The suppl�� voltage is mis-
sing, too low or has been
connected incorrectl��
Internal error is indicated
b�� the number of pulses
Test request via external
signal is active
The corresponding safet��
edge detected as having
been actuated
The corresponding safet��
edge detected as having
been interrupted
Error correction
Check connections and suppl�� voltage
According to the error indicator, switch off
the output, switch off the device or check the
suppl�� voltage
Check wiring of the TST_MOD and
TST_SIG connections
Check connection cable and state of the
corresponding safet�� edges
Check connection cable and state of the
corresponding safet�� edges