Error Diagnosis; Taking Out Of Service And Disposal - ASO Safety Solutions ELMON rail 39-726 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Relay

11. Error diagnosis

Only the green LED may illuminate if the supply voltage has been correctly connected. If one of the red LEDs
illuminate, there is an error in the system which can be pinpointed with the aid of the LED.
The yellow LEDs for the auxiliary outputs illuminate according to the DIP-switch settings.
LED
No LED
The supply voltage is missing,
illuminates
too low or has been connected
incorrectly
green LED
Internal error is indicated by the
flashes cyclically
number of pulses.
(pulse output)
red LED
The corresponding safety sensor
is illuminated
detected as having been actuated.
(CH1 or CH2)
red LED
sensor circuit interrupted , Sensor(s)
flashes fast
not connected,
(CH1 or CH2)
connected incorrectly or faulty.
red LED
error lock
flashes slowly
(CH1 or CH2)
If the error is not in the wiring, the function of the electronics can be tested by connecting an 8.2 kΩ resistor
*
to the sensor input on the switching unit. If the electronics work perfectly after performing the test, the
sensor must be checked using an ohmmeter. To do this, the connection of the sensor to the switching unit
must be disconnected and connected to an ohmmeter. The resistance must be 8.2 kΩ ±500 Ω when the
sensor is inactive and must not exceed 500 Ω when the sensor is active.

12. Taking out of service and disposal

The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and national regulations. Products can also be
returned to ASO, which will then dispose of them properly.
24
Error
Check connections and supply voltage:
- 24 V DC at terminals +24 V 0 V
- Correct polarity? +24 V at terminal +24 V
Tolerance range: ±10%
See -> Signal indicators
- Check the connections of the corresponding
- Check sensors *
- Check the connections of the corresponding
sensors (squeezed or brittle supply lines, etc.)
- Check sensors *
Perform manual reset
Error correction
sensors (squeezed or brittle supply lines, etc.)

Publicité