Safety Relay

4. Proper use

The switching unit can only fulfil its safety-related task if used properly.
The switching unit is intended to be used as protection in combination with safety contact mats, safety bumpers
and safety contact edges with 8.2 kΩ resistor for standby-current monitoring.
Any uses above and beyond these uses constitute improper use. The manufacturer assumes no liability for
damages arising from improper use.
The device may only be used in special applications with the manufacturer's express consent.

5. Application examples

Circuit diagram in zero-potential state. Sensor not actuated.
The auxiliary relay output is used for visualising the switching state of the safety contact edge.

5.1 Example of use for separated function

+24V
0V
Separated function

5.2 Example of use for combined function

+24V
0V
Shared function
18
8k2
8k2
S1
S2
+24V X1 X2
Y2 Y2
ELMON rail 39-726
0V
S11
S12
14
24 32 42
K1
Operation
mode:
K2
auto reset
8k2
8k2
S1
S2
+24V X1 X2
Y2 Y2
ELMON rail 39-726
0V
S11
S12
14
24 32 42
K1
Operation
mode:
K2
auto reset
31 41
Closed:
Switch S1 open
Opened:
Switch S1 closed
K1
K2
Closed:
Switch S2 open
Opened:
Switch S2 closed
31 41
Closed:
Switch S1 and S2 open
Opened:
Switch S1 or S2 closed
K1
K2
Closed:
Switch S1 and S2 open
Opened:
Switch S1 or S2 closed