Télécharger Imprimer la page

LELY ASTRONAUT A3 Next Manuel D'utilisation page 174

Publicité

9.12
Dépannage Flowcharts
9.12.1
Alarmes et appels téléphoniques
Key 2 pressed
Y
9-4
Initial call
delay passed?
Y
Dial phone number
Response time-out during call starts counting
say "Press 1 to play message"
Key 1 pressed
Y
Messages > 1
Y
Y
say "Number of alarm messages" <number>
say "Message number" <number>
say "Alarm message" "from CRS+" or "from 1101, 1102, etc"
N
1st
time playing
N
Y
All alarms done
Y
say "Press 1 to repeat, press 2 to repeat" counter n + 1
Y
Key 1 pressed
N
Key 2 pressed
Y
Y
remote reset code = 0
N
say "Please enter your reset code"
Timeout entering
reset code = 30 sec.
N
N
Key tones pressed
within 5 sec.
Y
N
Reset code
OK
Y
say "Reset code received"
Alarm message reset succesfully
Disconnect
N
Response
time-out during call
N
passed?
wait 2 seconds
N
N
N
N
Y
counter
n > 5
N
wait 2 seconds
Y
Alarm message reset not succesfully
Disconnect and dial next number
innovators in agriculture
Y
Dépannage

Publicité

loading