Cleaning Units - Maico PP 45 O Notice D'utilisation

Système de ventilation pushpull
Masquer les pouces Voir aussi pour PP 45 O:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UK | 10 Filter changes, unit cleaning
1. Disconnect units completely from the
mains power supply (switch off mains
fuse). Fit a warning notice to avoid the unit
being switched back on.
2. Remove front cover [1] by gently pressing
up locking lever on bottom of unit and
evenly pulling cover to the front and out.
Do not twist it.
3. Remove connector plug of motor connec-
tion cable.
NOTICE
Damage to pull-out belt [5] and filter seat
if pulled jerkily and torn. Pull drawer unit
evenly and carefully out of wall sleeve. Do
not pull jerkily / tear. Replace pull-out belt if
damaged.
4. Use pull-out belt [5] to pull entire drawer
unit out of wall sleeve and put down with
care. Support drawer unit from below with
one hand.
5. Pull the two air filters [7] and [12] out of the
filter seats.
6. Insert new air filters in the two filter seats.
The filters must be inserted behind the
3 brackets of the filter holder and must
be flush.
7. Support drawer unit from below with one
hand and slide into wall sleeve. The profile
seal [9] is used for fixing and avoidance of
false air. The motor connection cable must
not be strained when installed.
8. Fix motor connection cable in notch at side.
9. Insert connector plug of motor connection
cable.
10. Before putting on the front cover, the
shutter must always be open. Do this by
switching on the device and/or opening the
shutter.
11. Attach front cover [1] at top in two housing
studs and swivel down until cover engages
on locking lever.
12. Activate mains fuses and remove warning
sign.
The ventilation units start up.
36
13. Acknowledge the filter change on a con-
trol/the RC ventilation unit:
Press
RLS 45 O
RLS 45 K
Press the
keys together for 5 seconds.
Press SET key for 5 seconds.
PP 45 RC
Job done! The filter change is complete.

10.3 Cleaning units

● Clean ventilation unit
● Clean internal grille, fan and electronics
cover with a dry cloth.
Clean all ventilation units as follows:
1. Take out drawer unit  Chapter 10.2,
points 1. to 4.
2. Before taking out the two filter seats [6],
remove the two plastic rivets. To do this,
press out the rivet pin from inside with
a sharp object, press pin all the way out
from the outside and take off complete
rivet.
3. Remove the two filter seats [6]. Press
together the two locking levers of each
filter seat and pull the filter seat out of the
drawer unit.
4. Pull fan unit [8] out of drawer unit, blow
out, if necessary suction clean and clean
with a dry cloth.
5. Pull ceramic heat exchanger [11] out of
drawer unit – you may have to angle the
wall sleeve slightly to remove.
6. Rinse heat exchanger with clear water,
then leave to dry.
7. Clean wall sleeve.
8. If possible, suction clean inner part of
external cover.
key for 5 seconds.
and
every 2 years
.