UK | 1 System components

1 System components

The following ventilation units and room air
controls can be combined in a PP 45 system
and can have various sensors added. For
possible combinations  Installation
instructions.
Ventilation units and/or drawer units
PP 45 O
Object unit
PP 45 K
Comfort unit
PP 45 RC
Radio-controlled unit
Room air controls
RLS 45 O
Object room air control
(for PP 45 O/K)
RLS 45 K
Comfort room air control
(for PP 45 O/K)
DS 45 RC
Radio switch for PP 45 RC
(for PP 45 RC)
Ventilation units and/or drawer units
1
Front cover for internal housing
2
Shutter for PP 45 K/RC housing
3
Internal housing for PP 45 K/RC
3.1 Internal housing for PP 45 O
4
PP 45 O: rotary knob for shutter
5
Pull-out belt
6
Filter seat
7
G2 air filter (inside)
8
Complete fan unit, with connection
cable
9
Profile seal
10 Slide-in sleeve
11 Ceramic heat exchanger
12 G3 air filter (outside)
13 External cover / soffit element
14 Humidity sensor for PP 45 HYI, optional
(with PP 45 RC only for master unit)
15 PP 45 K/RC: servomotor for shutter
16 PP 45 RC: LEARN key
17 PP 45 RC: status LEDs orange/blue/red
18 PP 45 RC: SET key
22

2 Operation

2.1 Operating mode/functions

Operation with heat recovery WRG).
LED-based display on the RLS 45 O/K
control, for RC units with LED [17]
(orange). Units switch between venti-
lation and air extraction in a 60-second
cycle. With unit pairs, rooms are venti-
lated and air extracted at the same time.
Cross-ventilation without heat recovery
(e.g. summer operation). LED-based
display on the RLS 45 O/K control, for
RC units with LED [17] (blue). Ventila-
tion units run with fixed direction of air
flow in ventilation or air extraction mode.
Demand-driven operation: Automatic
operation to dehumidify the air or to
raise the room air quality to a certain
value limit. Function only available with
integrated/connected sensor. In WRG
or cross operating mode function is
switched on manually. Also applies
to RC units.
Intermittent ventilation with ventila-
tion level 5, only with
DS 45 RC
intermittent ventilation pos-
sible in every operating mode. Press
key for 2 seconds – the
slowly. On RC units, the current ope-
rating mode LED [17] flashes twice,
5 times. Operating time of 30 minutes.
The ventilation unit then switches back
to the ventilation level previously used.
Abort: Press a key.
Sleep mode with ventilation level 0,
RLS 45 K
only with
Sleep mode is possible in any opera-
ting mode. Press key for 2 seconds –
the
LED flashes slowly. On RC units,
all 3 LEDs light up and then go out one
after another. Operating time of 60 mi-
nutes. The ventilation unit then switches
back to the ventilation level previously
used. Abort: Press a key.
/
RLS 45 K
LED flashes
/
DS 45 RC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pp 45 kPp 45 rcRls 45 oRls 45 kDs 45 rc0095.0241

Table des Matières