instelwaarden/ setting values/ Einstellwerte
Valeurs de réglage/ Parametri/ ustawienia wartości
STEP NO. DESCRIPTION
Extract fan mode
19
switching input 1
20
Selection input 2
21
Minimum voltage input 2
22
Maximum voltage input 2
Conditions
23
switching input 2
Supply fan mode
24
switching input 2
Extract fan mode
25
switching input 2
26
Geo heat exchanger
Minimum temperature
geo heat exchanger
27
(Below this temperature
the valve opens.)
Maximum temperature
geo heat exchanger
28
(Above this temperature
the valve opens.)
Modifications reserved
Schütz continuously strives after improvement of products and reserves the right to change the specifications
without prior notice.
85
FACTORY SETTING EVOTHERM
300F PLUS
5
ON
0,0 V
10,0 V
0
5
5
UIT
5,0 °C
25,0 °C
EVOTHERM 300F
ADJUSTING RANGE
0 (= Extract fan off)
1 (= Absolute min. flow rate 50m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
OFF ( = Switching input 2 active)
ON (= 0 - 10 volt input 2 active)
0,0 Volt - 10,0 Volt
0,0 Volt- 10,0 Volt
0 (off)
1 (on)
2 (= On if conditions
bypass open satisfied)
3 (= Bypass control)
4 (= Bedroom valve)
0 (= Input fan off)
1 (= Absolute min. flow rate 50m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
0 (= Extract fan off)
1 (= Absolute min. flow rate 50m
2 (= Flow rate mode 1)
3 (= Flow rate mode 2)
4 (= Flow rate mode 3)
5 (= Multiple switch)
6 (= Maximum flow rate)
OFF (= Valve control geo heat
exchanger off)
ON (= Valve control geo heat
exchanger on)
0,0 °C - 10,0 °C
15,0 °C - 40,0 °C
12
GB
STEP
/h)
3
0,5 V
0,5 V
/h)
3
/h)
3
0,5 °C
0,5 °C