Siemens simodrive 2SP1202 Manuel De Configuration page 149

Edition 03/2007. electrobroche ecs.
Table des Matières

Publicité

Valve open
Air for
cone purge
Valve closed
active
Tool change
inactive
H (+24V)
Sensor S2
L (open)
rated pressure unclamp
Pneumatic
cylinder
rated pressure clamp
enabled
Enable
spindle rot
not enabled
Fig. 8-5
Diagramme de commande pour le changement d'outil manuel avec S2
Tableau 8-15 Traduction de la figure 8-5
Air for cone purge
additional manual release on request
additional manual clamp on request
Tool change
Sensor S2
Pneumatic cylinder
Enable spindle rot.
Valve open
Valve closed
Active
Inactive
if {pressure > min rated pressure} and
{S2 = L}
if {pressure = 0} and {S2 = H}
Open
Rated pressure unclamp
Rated pressure clamp
© Siemens AG 2007 All rights reserved
Electrobroche 2SP1 (PMS), Edition 03/2007, 6SN1197- -0AD04- -0DP3
remove tool
t wait to remove
L
Anglais
8.3
Changement d'outil
insert tool
H
Français
Air de nettoyage du cône
Desserrage manuel supplémentaire
Serrage manuel supplémentaire
Changement d'outil
Détecteur S2
Vérin pneumatique
Déblocage "mouvement de rotation de la
broche"
Vanne ouverte
Vanne fermée
Actif
Inactif
Si {pression > pression nominale mini} et
{S2 = L}
Si {pression = 0} et {S2 = H}
Ouvert
Pression nominale pour desserrage
Pression nominale pour serrage
Commande
t wait to enable
time
8-149

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Simodrive 2sp1204Simodrive 2sp1253Simodrive 2sp1255

Table des Matières