Values; Water Pressure - Daikin RoCon+ HP1 ETSH16P30D Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
7
Parameter settings
7.7.2

Values

[→ Main menu → Information → Values]
Parameters
Unit
Feed temper-
°C
ature, current
Feed temper-
°C
ature, target
Average out-
°C
side temperat-
ure
Hot water tem-
°C
perature, cur-
rent
Hot water tem-
°C
perature, tar-
get
Return flow
°C
temperature
Feed temper-
°C
ature HC cur-
rent
Feed temper-
°C
ature HC tar-
get
Feed temper-
°C
ature PHX
Feed temper-
°C
ature BUH
Outdoor tem-
°C
perature (op-
tional)
Refrigerant
°C
temperature
Volume flow
l/h
Water pres-
bar
sure
Tab. 7-20 Parameter in the "Values" menu
INFORMATION
Depending on the device type, the system configuration
and the status of the device software, individual listed in-
formation parameters cannot be displayed or can be dis-
played at a different parameter level.
7.7.3

Water pressure

[→ Main menu → Information → Pressure]
Parameters
Unit
Water pres-
bar
sure
Tab. 7-21 Parameter in the "Water pressure" menu
Operating Instructions
44
Description
The current feed temperature of the heat generator (t
The current target temperature of the heat generator is displayed in °C.
The current outside temperature is displayed in °C.
The current temperature of the hot water storage tank is displayed in °C. If
no hot water function is activated, "----" is displayed.
The current target temperature for domestic hot water preparation is dis-
played in °C. If no hot water function is activated, "----" is displayed. Here,
the current target value is always the maximum value of all requests relev-
ant for this hot water circuit.
The current return flow temperature of the heat generator is displayed in
°C. If no respective sensor is connected to the heat generator, "----" is dis-
played.
The temperature of the direct HC (t
port, otherwise t
) in °C.
V1
The (feed) target temperature of the direct HC is displayed in °C.
The current feed temperature of the heat generator in the outdoor unit is
displayed.
The current feed temperature of the heat generator after the optional
backup heater is displayed.
The current outdoor temperature measured by the optional outdoor tem-
perature sensor is displayed.
The current refrigerant temperature of the outdoor unit (liquid) is displayed.
The filtered value of the current water-side volume flow is displayed.
If glycol is added and the internal flow switch is active, 0 l/h is displayed.
The current water pressure is displayed.
Description
The current water pressure is displayed in bar.
) is displayed in °C.
V1
is displayed with active heating sup-
V2
Factory
Incre-
Access
setting
ment
BE HF
-
1 °C
S
S
-
0.1 °C
S
S
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
0.1 °C
S
S
-
1 l/h
S
S
-
0.1 bar
S
S
Factory
Incre-
Access
setting
ment
BE HF
-
0.1 bar
S
S
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN