Information; Overview - Daikin RoCon+ HP1 ETSH16P30D Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
7.7

Information

[→ Main menu → Information]
7.7.1

Overview

[→ Main menu → Information → Overview]
Parameters
Setting range
Min / Max
Mode
No request
Heating
Cooling
Domestic hot
water prepara-
tion
Defrost
External re-
quest
No external
mode
Low rate
High rate
SGN
SG1
SG2
SG3
Room thermo-
stat/Interlink
Off
Request
No heat request If [Room thermostat] = Yes
IL1
IL2
Quiet mode
Heating sup-
Off
port
On
Status, heat
Off
circulation
On
pump
PWM pump
25 – 100%
BUH current
-
output
3UVB1 posi-
-
tion
3UVDHW pos-
-
ition
Heat generator
-
type
Software no.
-
B1/U1
Software no.
-
controller
Glycol
No glycol added No glycol present in the heating circuit
Glycol added
Tab. 7-19 Parameter in the "Overview" menu
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
Description
Current mode of the heating pump.
External request:
Heat pump operates in normal operation.
EVU function HT/NT active and low rate.
EVU function HT/NT active and high rate.
EVU function Smart grid active, normal operation.
EVU function Smart grid active, discharge: No heat pump operation, no
frost protection function.
EVU function Smart grid active, switch-on recommendation, operation at
higher target temperatures, inexpensive electricity.
EVU function Smart grid active, switch-on command and storage tank
charging to 70 °C, inexpensive electricity
Room thermostat/Interlink:
If [Interlink function] = On: frost protection only; otherwise: Off
If [Room thermostat] = Yes
If [Interlink function] = On: Normal feed target temperature
If [Interlink function] = On: In heating mode increased feed target temperat-
ure, in cooling mode reduced feed target temperature
Status of the Quiet mode
Status of the heating support
Output of the internal heating circulation pump (on/off)
Output of the internal heating circulation pump
Current output of the optional backup heater in kW
The current position of the 3-way mixer valve 3UVB1 is displayed in %.
The current position of the 3-way mixer valve 3UV DHW is displayed in %.
The configured type of the heat generator is displayed.
The software and version of the operating unit are displayed.
The software number and version of the controller PCB are displayed.
Glycol present in the heating circuit
7
Parameter settings
Factory
Incre-
Access
setting
ment
BE HF
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
-
S
-
1%
S
-
1%
S
-
-
S
-
-
S
-
-
S
Operating Instructions
S
S
S
S
S
S
S
S
S
S
S
S
S
43