Time Program - Daikin RoCon+ HP1 ETSH16P30D Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
7.4

Time Program

[→ Main menu → Time program]
Parameters
Setting range
Min / Max
Party
0 – 360 min
Absent
0 – 360 min
Holiday
Date 1st day
-
Date last day
Public holiday
Date 1st day
-
Date last day
Heating circuit
See
Chap. 4.3
auto. 1
Heating circuit
See
Chap. 4.3
auto. 2
Hot water
See
Chap. 4.3
auto. 1
Hot water
See
Chap. 4.3
auto. 2
Circulation
See
Chap. 4.3
program
Sound pro-
See
Chap. 4.3
gram
0 – 3
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
Description
This operating mode can be used to set a unique time for temporarily ex-
tending the heating time of the internal heating circuit.
This operating mode can be used to set a one-off time for temporary regu-
lation to the parametrised absence temperature.
The internal heating circuit provides continuous (24 h per day) regulation to
the parametrised absence temperature ([Reduce room temperature] para-
meter).
A calendar function can be used to enter a time period of absence.
A calendar function can be used to enter a time period of presence.
During this period of time, regulation is carried out exclusively according to
the settings for "Sunday" in the [Heating circuit auto. 1] and [Hot water
auto. 1] time programs.
In this menu, the 1st time program can be parametrised for the internal HC.
3 switching cycles with a resolution of 15 minutes can be set. A separate
entry for each weekday is possible. Format: (on) hh:mm – hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
In this menu, the 2nd time program for the internal HC can be paramet-
rised. 3 switching cycles with a resolution of 15 minutes can be set. A sep-
arate entry for each weekday is possible. Format: (on) hh:mm – hh:mm
(off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
This menu can be used to parametrise the 1st time program for domestic
hot water preparation. 3 switching cycles with a resolution of 15 minutes
can be set. A separate entry for each weekday is possible. Format: (on)
hh:mm – hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
This menu can be used to parametrise the 2nd time program for domestic
hot water preparation. 3 switching cycles with a resolution of 15 minutes
can be set. A separate entry for each weekday is possible. Format: (on)
hh:mm – hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
This menu can be used to parametrise a timer program for the circulation
pump. 3 switching cycles with a resolution of 15 minutes can be set. A sep-
arate entry for each weekday is possible. Format: (on) hh:mm – hh:mm
(off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
In this menu, a time program can be parametrised for various stages of the
heat pump quiet mode. 3 switching cycles with a resolution of 15 minutes
can be set. A separate entry for each weekday is possible. Format: (on)
hh:mm – hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and Monday
to Sunday can be parametrised.
A noise level can be assigned to each switching cycle (0: no noise reduc-
tion, 1: Min. noise reduction, 2: Med. noise reduction , 3: Max. noise reduc-
tion).
Note: This program can therefore only be set by the installer.
7
Parameter settings
Factory
Incre-
Access
setting
ment
BE HF
0 min
15 min
E
0 min
15 min
E
-
1 day
E
-
1 day
E
See
15 min
E
Tab. 4-3
See
15 min
E
Tab. 4-3
See
15 min
E
Tab. 4-3
See
15 min
E
Tab. 4-3
See
15 min
E
Tab. 4-3
0
15 min
N
Operating Instructions
E
E
E
E
E
E
E
E
E
E
31

Publicité

Table des Matières
loading

Table des Matières