Mixer module

In addition to the direct HC, the heating system can be extended by
additional HCs using EHS157068 mixer modules. These additional
HCs can be configured independently of the direct HC. The configur-
ation is similar to the configuration of the direct HC (see
Only a limited selection of parameters and functions is available (see
Chap.
9.2).
The optional EHS157068 mixer module does not have its own con-
trol unit. For configuration and operation, it must be connected via a
CAN bus line to the RoCon+ controller installed in the heat generator
or a EHS157034 room station. The mixer module can be operated in
terminal mode from both operating units (see
A unique device ID (≥ 1) must be set on the address switch of the
mixer module (see
Fig.
9-1) for the HC to be controlled by this mixer
module, which must be synchronised with the [Heating circuit as-
signment] parameter of the mixer module (see
Fig. 9-1
Setting the device ID for the EHS157068 mixer module
The current operating status can be determined directly on the
EHS157068 mixer module (see
Fig. 9-2
Explanation of symbols for EHS157068 status displays
Item
LED
Description
1
Red
Flashing: Internal error
(The error code is communicated to the relevant
control unit via the CAN bus)
On: Undervoltage of the internal clock after a power
failure (>10 h)
2
Green
On: Display during operation, mixer module
switched on
3
Green
On: CAN communication
4
Green
On: Mixer circuit pump switched on
5
Green
On: Mixer valve "Open" is activated
6
Green
On: Mixer valve "Closed" is activated
Tab. 9-1
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
Chap.
4).
Chap.
4.8).
Tab.
4-7]).
Fig.
9-2).
9.1
Mixer module start screen
(terminal function)
Fig. 9-3
Mixer module start screen
The start screen for the mixer module
of the RoCon+ HP start screen. The meaning of the icons is the
same
Tab.
3-3, but the mixer temperature is the only system temper-
ature displayed
(Fig.
9-3, item 1).
The start screen for the mixer module is displayed in the menu
[→ Main menu → Terminal → Mixer #X]. Briefly pressing the rotary
switch switches to the mixer menu. A long press of the rotary switch
switches to the menu of the local control panel.
9.2

Mixer valve parameter overview

Menu: Operating mode
see
Chap.
6.1.
Menu: User
Room
Reduce
Reduce
Fig. 9-4
Parameter in menu: "User"
Menu: Time program
Party
Absent
Holiday
Public holiday
HC auto 1
Heating circuit auto. 1
HC auto 2
Heating circuit auto. 2
Fig. 9-5
Parameter in menu: "Time program"
9
Mixer module
(Fig.
9-3) is a reduced version
Room temperature target 1
Room temperature target 2
Room temperature target 3
Reduce room temperature
Room temperature absent