Time Program Reset; Settings - Daikin RoCon+ HP1 ETSH16P30D Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
4
Function
Heating circuit auto. 1 and Heating circuit auto. 2
[→ Main menu → Time program → HC auto 1/HC auto 2]
The time programs for the HC can be parametrised in these menus.
Three switching cycles can be set per day, to which the [Room tem-
perature target 1/2/3] parameters are assigned. Outside the switch-
ing cycles, it is controlled to the [Reduce room temperature] setpoint.
The entry can be made separately for each individual weekday or in
week segments.
Hot water auto. 1 and Hot water auto. 2
[→ Main menu → Time program → DHW auto 1/DHW auto 2]
The time programs for the domestic hot water preparation can be
parametrised in these menus. Three switching cycles can be set per
day, to which the [Hot water temperature, target 1/2/3] parameters
are assigned.
Circulation program
[→ Main menu → Time program → Circulation]
A time program for an optionally connected circulation pump can be
parametrised in this menu. 3 switching cycles per day can be set.
Time period
Temperature setting
Monday – Friday
Saturday, Sunday
Monday – Friday
Saturday, Sunday
Temperature setting
Monday – Sunday
Monday – Friday
Saturday, Sunday
Monday – Friday
Saturday, Sunday
Monday – Sunday
Tab. 4-3
Factory setting of the permanent time programs
4.3.3

Time program reset

[→ Main menu → Time program → TP reset]
This menu can be used to reset the time programs to factory set-
tings. To do this, select the respective time programs and then con-
firm the selection with the Confirm button on the second menu page.
Operating Instructions
14
Switching cycle 1
On
Off
[Room temperature target 1]: 20 °C [Room temperature target 2]: 20 °C [Room temperature target 3]: 20 °C
"Heating circuit auto. 1"
06:00
22:00
07:00
23:00
"Heating circuit auto. 2"
06:00
08:00
07:00
23:00
Domestic hot water preparation
[Hot water temperature target 1]:
60 °C
"Hot water auto. 1"
05:00
21:00
"Hot water auto. 2"
05:00
21:00
06:00
22:00
"Circulation program"
05:00
21:00
06:00
22:00
"Sound program"
- - : - -
- - : - -
INFORMATION
Use of circulation lines not permitted in France!
Sound program
INFORMATION
During quiet mode, the output in room heating and room
cooling mode decreases so that it may no longer be pos-
sible to achieve pre-set target temperature values.This pro-
gram can therefore only be set by the installer.
In this menu, a time program can be parametrised for various stages
of the heat pump quiet mode. 3 switching cycles with a resolution of
15 minutes can be set. A separate entry for each weekday is pos-
sible. Format: (on) hh:mm – hh:mm (off)
Also, the cycles from Monday to Friday, Saturday to Sunday and
Monday to Sunday can be parametrised.
A noise level can be assigned to each switching cycle (0 - no noise
reduction; 1 - min. noise reduction; 2 - med. noise reduction; 3 -
max. noise reduction).
Factory settings
The permanent time programs are preset according to .
Switching cycle 2
On
Off
Room heating
[Reduce room temperature]: 10 °C
- - : - -
- - : - -
- - : - -
- - : - -
16:00
22:00
- - : - -
- - : - -
[Hot water temperature target 2]:
60 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
4.4

Settings

[→ Main menu → Settings]
The basic settings of the controller and the system are made in this
menu. This includes the integration of optional and external compon-
ents. Depending on the access authorisation (user or expert), differ-
ent parameters are available.
Switching cycle 3
On
Off
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
[Hot water temperature target 3]:
60 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN

Publicité

Table des Matières
loading