Parameters
Setting range
Min / Max
Hot water
0 – 180 min
blocking time
Hot water hys-
2 – 20 K
teresis
Wait time ext.
20 – 95 min
heat generator
Solar function
Off
On
Circulation
pump control
Off
On
Circulation
pump interval
Off
1 – 15 min
Anti-legionella
day
Off
Monday
...
Sunday
Daily
Anti-legionella
00:00 – 23:45 Setting of the start time for thermal disinfection of the hot water storage
start time
Anti-legionella
60 – 70 °C
temperature
Tab. 7-17 Parameter in the "Hot water" menu
Daikin RoCon+ HP
Daikin controller RoCon+ HP1
008.1447899_00 – 09/2019 – EN
Description
Setting of the blocking time after completion or cancellation of a domestic
hot water preparation cycle. The repeat request for domestic hot water pre-
paration is operated after this blocking time has elapsed at the earliest.
Hot water charging switching threshold
Setting of the temperature difference by which the temperature in the hot
water storage tank may fall in comparison with the currently valid hot water
target temperature [Hot water temperature, target] before the heat pump
for hot water charging is to be activated.
Delay time as of which the additional heat generator may support the heat
pump in hot water charging (see
Used to reduce the target temperature of the hot water storage tank in or-
der to increase the yield of a connected solar system. The target value of
the hot water temperature is set as a function of the outside temperature
and in compliance with the safety functions. The following parameters are
also defined: Hot water hysteresis = 5 K; building insulation = Normal
Deactivated
Activated if the switching contact EXT (J8) is also closed.
Setting for the control of a circulation pump. Use in France not permitted!
Optional circulation pump is synchronously controlled to the active switch-
ing time program for domestic hot water preparation.
Optional circulation pump is controlled according to the [Circulation pro-
gram] switching time program.
Setting of the interval control for an optional circulation pump. Use in
France not permitted!
Deactivated. The circulation pump runs permanently during the release
times of the assigned switching time program ([Circulation pump control]
parameter).
The circulation pump runs clocked (clock cycle ratio: pump runtime = set-
ting value each 15 min).
Setting of the day for thermal disinfection of the hot water storage tank.
No thermal disinfection
Day of thermal disinfection
Daily thermal disinfection
tank (format hh:mm).
Setting of the hot water target temperature during thermal disinfection of
the hot water storage tank.
Chap.
4.5).
7
Parameter settings
Factory
Incre-
Access
setting
ment
BE HF
30 min
10 min
N
7 K
1 K
E
50 min
1 min
E
-
E
-
E
Off
1 min
E
Off
-
E
03:30
15 min
N
65 °C
1 °C
N
Operating Instructions
E
E
E
E
E
E
E
E
E
41