Description Of The Machine; Monoblock Air Conditioning - Tekno Point WINE-14 Manuel D'utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

manuale di istruzioni uso e manutenzione WINE-14
addition, local regulations must be taken into account with regard to the installation of external
units on the external walls of buildings.
The manufacturer declines all responsibility for any
damage that could be caused directly or indirectly to
people and / or things as a result of failure to comply with
these instructions or failure to use unqualified personnel.
The WINE-14 air conditioning unit was designed and
built in Italy by assembling commercial and other self-
made products and complies with current regulations.
The "machine" before leaving the factory is subjected to
testing with a pressurized gas circuit, powered
electrically in order to verify the correct operation of each
component and the functionality of the safety devices.

3. DESCRIPTION OF THE MACHINE

The WINE-14 air conditioning unit, which consists of the
monoblock air conditioner and the humidifier, has been
designed and built to be installed in the cellar with the
aim of preserving, refining and optimally aging the wine
in cask and / or bottle.
The unit, interacting automatically between the two
components and with the aid of the digital controller, is
able to maintain the temperature of 14/16 ° C (average
of use) and restore the missing humidity between the measured and the desired humidity which
usually fluctuates between 65-75%.
sockets and the temperature probe already wired
a.
Monoblock air conditioner
The unit is built entirely in AISI304 STAINLESS STEEL outside, the evaporator is of the high
efficiency finned pack type, made internally of copper pipes and aluminum fins protected by a
suction net that holds any foreign bodies in place . The delivery fans on the cellar side are helical.
The unit must be connected to the outside via two 125 mm diameter ducts. The outdoor air
treatment fan is centrifugal. The unit provides a condensation drain.
www.teknopoint.com
On the top front there is the environment recirculation air
expulsion grid, in the center the sheet for cleaning the internal
filter and at the bottom the digital controller for programming the
T ° and% humidity.
On the back, at the top there is the dust-proof net to protect the
evaporator, then the support bracket, the hose-holder and the
condensate drain-pipe in addition, the two male connections for
d 125 air intake and exhaust pipe, on the right the group the
Pag. 3