Safety Precautions - Tekno Point WINE-14 Manuel D'utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

manuale di istruzioni uso e manutenzione WINE-14
Heat exchangers
Cell side electric fan, flow rate:
External side electric fan type,
External dimensions
Humidifier water flow rate
Sound level
Refrigerant, type
Unit weight
Refrigerant charge
(*) value referred to a properly insulated room, in particular to the perimeter walls, floor, ceiling
and entrance door;
(**) plate potential
NB: the air conditioner does not have the "dehumidifier" function instead, the cold circuit
battery can extract humidity but only during compressor operation.
In the event that the room has humidity values greater than 80% it could be
necessary to install a dehumidifier that can be connected in the appropriate
terminal blocks of the electrical panel terminal board, operation to be carried out in the
company premises.
5. INSTALLAZIONE
a.
to. safety precautions
Warning against possible risks of injury, pollution or damage to materials in the event of non-
compliance with the instructions, therefore:
• use protective gloves;
• use protections during brazing operations so as not to damage the equipment with a blowtorch;
• handle refrigerant gases in order to avoid dispersion in the atmosphere;
• use portable and work equipment according to the law;
• check that the electrical system to which the machine will be connected is in compliance with
the law paying particular attention to the efficiency of the grounding;
• connect the machine power supply to a differential switch, the absence of this component could
cause an electric shock;
• avoid installing the air conditioner in places where there may be gas leaks, because it could
cause an explosion;
• avoid pulling, cutting or crushing the power supply or connection cables and do not bring them
near heat sources;
• do not approach the equipment with wet hands.
• disconnect the power supply plug during maintenance operations;
• avoid using water to clean the air conditioner which could infiltrate and cause a short circuit;
www.teknopoint.com
Battery with
aluminum fins
copper tubes
(mc/h)
Helical - 300
(mc/h)
centrifugal - 300
456 x 289 x h 822
l/h
1
dB (A)
≤ 55
R134a
(kg)
40
(kg)
0,300
Pag. 6

Publicité

Table des Matières
loading

Table des Matières