Test Outputs; Test Triggers; Test Line; Test Supply - Abus AZWG10020 Instructions D'installation Et De Service

Transmetteur téléphonique gsm/rtc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 109
"Ack Received"
"Sending SMS"
"SMS OK"
"SMS Fail"
"Wait"
"Not available"
"Wait"
"FAIL"
12.10.2

Test Outputs

You check the operation of the four outputs using this menu item. Each
output can be activated and deactivated individually.
Press the number keys 1 to 4 to individually switch each output. The LEDs
OP1 or OP2 light up when output 1 or 2 has been activated.
12.10.3

Test Triggers

You use this menu item to check the correct wiring of the inputs.
You now trigger the respective inputs. When correctly triggered, the device
will display the associated letter A–H of the input on the display.
Display when idle
*/*/*/*/*/*/*/*
Display with correct triggering of all 8 inputs.
A/B/C/D/E/F/G/H
In this test, no telephone connections are set up.
12.10.4

Test Line

Here you check the analog telephone connection.
Press ENT. The display shows either
"LINE OK" or "LINE FAIL"
There is a line failure if the telephone line is not available for more
than 40 seconds.
For the device, the telephone line is available when the voltage on
the a/b line or on terminals A and B > 3 V.
12.10.5

Test Supply

Here you check the value of the supply voltage.
Press ENT. The current value of the supply voltage value is displayed (such
as 12.3 V).
A person on the other end of the line has pressed the
8 key. This acknowledged the call.
The device is currently sending an SMS message.
The SMS message was received by the SMS service
center.
The device could not send the SMS message.
The device is waiting for initialization of the GSM
modem.
GSM problem (such as an error in the subscriber's
telephone number).
The device is waiting for data from the GSM network.
Time-out during setup of the GCM connection.
38 UK

Publicité

Table des Matières
loading