10.10 Connecting expansion modules

The 8-zone wire expansion modules and the 8-zone radio
expansion modules are connected to the 4-wire bus as
follows.
expansion modul
Make sure when connecting the 8-zone wire expansion
module that the zone terminations (CC / DEOL) from the
alarm centre and the expansion module are identical.

10.11 Addressing of expansion modules:

A determined range of zones must be assigned to each
expansion module. Two modules must not occupy the
same zone range. The zone ranges are addressed via the
jumpers on the expansion modules.

10.12 Walk test

The OP3 output must be appropriately programmed for
the walk test (function 83, option 5). If the user activates
the walk test function then the LED for motion detection is
activated at the detector.
motion detector 1
motion detector 2
walk test
walk
test

10.13 Detector alarm memory

For the alarm memory function, e.g. for motion detectors,
the OP3 output must be appropriately programmed
(function 83, option 3). The first detector in the line that
triggers the event can store and signalise this.
motion detector 1
motion detector 2
21