Abus Terxon MX Instructions D'installation page 169

Masquer les pouces Voir aussi pour Terxon MX:
Table des Matières

Publicité

076 Behaviour of exit mode internal (D)
To change the property of the exit mode for internal active
(D):
1. On the control unit, enter:
2. The LCD display shows: 076: D=Low Tone
3. Via the keypad, select from the following items
and press:
D=Low Tone
0
The acoustic signal during the exit
delay time is emitted at half volume.
D=Instant
During internal activation, the alarm
1
centre is internally activated
immediately – i.e., without delay.
D=Silent
No acoustic signal is emitted during the
2
delay time. Following expiry of the delay
time, the alarm centre emits a brief
signal.
D=A
3
The initial mode for internal active B is
as for the initial mode of overall active A
In a partitioned system
D=Timed
Activation of partition D after exit time
0
(command 79). A connected key switch
at the control unit shortens the exit time
when activated
D=Terminated
Activated via key switch connected to
1
the control unit. The exit time is
unlimited.
D=Final Door
2
Activation of the partition by closing the
last door detector
D=Instant
3
Active without delay time
D=Silent
Use command 79 for the exit time. The
4
control unit emits a double beep when
the time has expired.
076
65
D=Lock Set
5
Key switch (see command 39)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
077 Alarm behaviour for internal (D)
To change the alarm property for internal active (D):
1. On the control unit, enter:
2. The LCD display shows: 077: D = Internal
3. Via the keypad, select from the following items
and press:
D=Keypad
0
Only the control units are activated.
D=Internal
1
On alarm, the control units and the
internal alarm are activated.
D=Local
On alarm, the control units, the internal
2
alarm and the external siren are
activated.
D=Full
On alarm, the control units, the internal
3
signalling, the external sirens and the
exits are activated.
In a partitioned system
D=Keypad
0
Only the control units are activated.
D=Local
1
On alarm, the control units, the internal
alarm and external sirens are activated.
D=Full
2
Control unit + internal + external +
telephone dialler
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
077
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Az4100Az4150