5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
037 Sabotage Report deactivated
To change this feature, proceed as follows:
1. On the control unit, enter:
2. The LCD display shows: 037:Day Tamp OFF
3. Via the keypad, select from the following items
and press:
Day Tamp OFF
In case of tampering when the alarm
0
centre is deactivated, this only issues
an internal alarm.
Day Tamp ON
In case of tampering when the alarm
1
centre is deactivated, this issues an
internal alarm and reports the
tampering to the central station.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
038 System Sabotage Reset
To change the property of the System Sabotage Reset:
1. On the control unit, enter:
2. The LCD display shows: 038: EnSysTmp ON
3. Via the keypad, select from the following items
and press:
EnSysTmp OFF
In the event of a system sabotage, you
0
can reset the alarm centre by entering
the user code.
EnSysTmp ON
In the event of a system sabotage, you
1
can reset the alarm centre by entering
the installer code.
4. Confirm your input. On the control unit, enter:
.
037
038
53
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
039 Exit mode for overall activated (A)
To change the property of the exit mode for overall
activated:
1. On the control unit, enter:
2. The LCD display shows: 039: A=Timed
3. Via the keypad, select from the following items
and press:
A=Timed
After the alarm centre is activated, the
programmed exit delay time starts. At
0
the end of the delay time, the alarm
centre is activated. If zones are open at
this time, an alarm is triggered.
A=Terminated
After the alarm centre is activated, the
exit delay time starts. The delay time
runs until a button connected to a
1
control unit is pressed, which ends the
exit delay time manually. The exit delay
time ends seven seconds after the
button is pressed.
A=Final Door
After the alarm centre is activated, the
exit delay time starts. The delay time
2
runs until a zone with the entry/exit
property is closed. The exit delay time
ends seven seconds after the zone is
closed.
A=Lock Set
After the alarm centre is activated, the
delay time starts. The delay time runs
3
until a zone with the entry/exit property
is closed and, after the zone has
closed, a contact connected to the
control unit is opened.
4. Confirm your input. On the control unit, enter:
.
039