4. Confirm your input. On the control unit, enter:
UK
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
062 Behaviour of exist mode internal active
(B)
To change the property of the exit mode for internal active
(B):
1. On the control unit, enter:
2. The LCD display shows: 062: B=LEISE
3. Via the keypad, select from the following items
and press:
0
1
2
3
In a partitioned system
0
1
changes its zone property during
internal activation to entry/exit and
starts the delay time if the zone triggers
and during active internal activation.
062
Low Tone
The acoustic signal during the exit
delay time is emitted at half volume.
Instant
During internal activation, the alarm
centre is internally activated
immediately – i.e., without delay.
Silent
No acoustic signal is emitted during the
delay time. Following expiry of the delay
time, the alarm centre emits a brief
signal.
B=A
The initial mode for internal active B is
as for the initial mode of overall active A
B=Timed
Activation of partition B after exit time
(command 65). A connected key switch
at the control unit shortens the exit time
when activated
B=Terminated
Activated via key switch connected to
the control unit. The exit time is
unlimited.
B=Final Door
2
Activation of the partition by closing the
last door detector
B=Instant
3
Active without delay time
B=Silent
Use command 65 for the exit time. The
4
control unit emits a double beep when
the time has expired.
B=Lock Set
5
Key switch (see command 39)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
063 Alarm behaviour for internal active (B)
To change the alarm property for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 063: B=Keypad
3. Via the keypad, select from the following items
and press:
B=Keypad
0
Only the control units are activated.
B=Internal
1
On alarm, the control units and the
internal alarm are activated.
B=Local
On alarm, the control units, the internal
2
alarm and the external siren are
activated.
B=Full
On alarm, the control units, the internal
3
signalling, the external sirens and the
telephone dialler are activated.
In a partitioned system
B=Keypad
0
Only the control units are activated.
B=Local
1
On alarm, the control units, the internal
60
063