7. Presentation of the cabinet - Intended use (Fig. 1)
Intended
The cabinet is intended to be used by qualified personnel, instructed and
trained by the employer in its use and in the risks it may entail.
recipient
Intended Use
Colonia 3 and Mini Colonia are part of a line of "island" cabinets suitable
for the storage and sale of ice-cream and frozen food prepared for supply
with remote condensing unit.
Liability
The Client or employer assumes full responsibility regarding the
qualification and mental and/or physical state of the employees assigned to
use and maintain the unit.
DANGER! Electrical equipment. Electrocution.
The norms and laws in force must be complied with during installation and use.
i
Carefully read the manual before use and instruct the persons appointed to the various
operations (transport, installation, maintenance, etc.), each in accordance to his
responsibility based on the indications reported.
This manual MUST IN NO WAY be used to address the cultural or intellectual
shortcomings of staff that interact with the cabinet.
8. Standards and certifications, declaration of conformity
All the models of refrigerated cabinets described in this user manual of the series:
Colonia 3 and Mini Colonia meet the essential requirements of safety, health and protection
required by the following European directives and laws:
Directive
Machinery 2006/42 CE
Electromagnetic
Compatibility 2004/108/CE
Low Voltage 2006/95/CE
RoHs Directive 2011/65/CE;
(restricted use of certain
hazardous substances in
electrical and electronic
equipment)
European Regulations
EC-1935/2004
(on materials intended to
come into contact with the
goods)
i
Article 3 paragraph 3 of directive EEC 97/23 (PED) is not applicable to these cabinets.
The performance of these refrigerated cabinets has been determined with tests conducted in
accordance with the standard:
UNI EN ISO 23953-2: 2006 under the environmental conditions corresponding to climatic
class 3 (25°C, 60% R.H.) see table:
34
Harmonised standards applied:
EN ISO 14121:2007; EN ISO 12100-1:2005; EN ISO 12100-2:2003; EN
378-2:2009; EN 378-3:2008; EN 378-4:2008; EN 60079-10-1:2010
EN 61000-3-2:2006; EN 61000-3-12:2005; EN 55014-1:2006; EN
55014-2:1997;
EN 60335-1:2008; EN 60335-2-89 :2002/A2:2007
EN 50581:2012
EN 1672-2