Ecolab My Control Manuel D'utilisation page 151

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WE Parameters
Fig. 41: Configuration -> Machine -> WE -> WE Parameters
Select the WE
WE parameters:
n
Stop signal delay: configuration of the delay for signal activation
n
"ON HOLD" of the WE
n
Water counters 1 calib. (L/pulse)
n
Water counters 2 calib. (L/pulse)
n
pH calibration (1/100 pH)
n
Temperature calibration (1/10°C)
n
Manyfold rinse time (s) Water FS number
n
4 – 20 mA signal type (4-20 mA= green) (0-20 mA= grey)
n
Select lines on Manyfold (push on to be select in green)
WE mode:
n
Progr by time:
n
T.O.M. mode WE:
n
Signal Stop WE act:
n
Sig. Stop used:
Choice on any push button to go in the request mode.
WE mode:
n
Mode 1: Prg = Binary, Step=One signal, Start generated by first step
n
Mode 2: Prg & Start = Miniterminal, Step = One signal
n
Mode 3: Prg = Miniterminal, Step=One Signal, Start generated by first step
n
Mode 4: Prg = Miniterminal, Step=Binary code, Start generated by first step
n
Mode 5: Prg & Start = Binary, Step=1 Sig., Start not gener. by first step
n
Mode 6: TOM mode only
Available Menue:
Back to Configuration/Machine/WE:
Ä Chapter 7.2.4.2.1 'WE' on page 49.
see chapter
Back to Main Screen:
Ä Chapter 7.2 'System Start - Main Screen' on page 34.
see chapter
53
Software description
417101971 Rev. 2-02.2019