6.2.4
Displays – Date and time
Press and hold for 3 seconds on the time/date displayed (Fig. 9, Pos. 1) on the control's
touch screen. The field to change the date and time will appear.
Enter the desired data and confirm with the Transmit Data button.
Fig. 9: Date and time
1
Adjusted time/date
2
Field to change date and time
6.2.5

Manual mode - Pumps

Press the "Pump" button (
on page 28,Fig. 7, Pos. 1) on the control's touch screen.
Fig. 10: Manual mode - Pumps
1
Pump number
2
Dosing point
(1-16->WE1-WE16, 17-20->TUN1, 21-24->TUN2)
3
Manual dosing time
4
Green: line is free, red: line is in use
5
Pump flow cut-off
3
Ä Chapter 6.2.2 'Changeover to Manual mode / Alarms'
6
7
8
9
A
B
29
Confirm button (to confirm changed data)
Enable manual flush
Start/Stop
Pump running time
Pulse counter (optional flow meter selected / activated)
Page back
Return to Main menu