––– STEP 5 –––
The following chapters describe different ways of customising AVIO to
make it suitable for specific application requirements.
5.1 – ADVANCED ADJUSTMENTS
5.1.1 – Adjusting the parameters with the radio transmitter
The radio transmitter can be used to adjust certain control unit operation
parameters: there are four parameters and each of them can have four
different values:
1) Pause time: time during which the door remains open (in the auto-
matic closing mode).
2) Motor speed: to set the closing and opening speeds.
3) Motor force: maximum force beyond which the control unit recog-
nises an obstacle and reverses the movement.
4) "Step-by-Step" function (SbS): sequence of movements associated
to each "Step-by-Step" command.
5)Exclusion position: defines the minimum height, in relation to the full
closure, below which the obstacle detection function is not carried out.
The parameter adjustment operation can be performed using a radio
transmitter, provided it is memorised in mode 1.
If no transmitter memorised in Mode 1 is available, you can memorise one
just for this phase and delete it immediately afterwards (see paragraph
5.5.1 "Memorisation Mode 1" and paragraph 5.5.4 "Deleting a radio
transmitter").
W A R N I N G :
W ARNING: when using the transmitter to make adjustments you need
to give the control unit time to recognise the radio command; this means
that the buttons must be pressed and released slowly, held down for at
least one second, then released for one second and so on.
1 Press buttons T1 and T2 on the radio transmitter simultaneously for at
least 5 seconds.
Parameters
Pause Time
Motor speed
Motor force
"Step-by-Step"
function (SbS)
Exclusion position
Note: "
" default function.
5.1.2 – Checking the parameters with the radio transmitter
With a radio transmitter memorised in Mode 1 you can check the
values set for each parameter at any time by following the sequence
described below:

ADDITIONAL INFORMATION

Setting
10s
20s
40s
80s
Opening = 75
%, Closing= 25 %
Opening = 100 %, Closing = 50 %
Opening = 100 %, Closing = 75 %
Opening = 100 %, Closing = 100 %
Low
Medium-low
Medium-high
High
"Open"-"Stop"-"Close"-"Stop"
"Open"-"Stop"-"Close"-"Open"
"Open"-"Close"-"Open"-"Close"
"Open"-"Open"-"Open" (opening only)
Minimum
Medium-low
Medium-high
Maximum
81
T1
2 Release the two buttons.
3 Within 3 seconds, perform the action described in Table 9 based on the
parameter to be modified
Example: to set the pause time at 40 s.
1
st
Press buttons T1 and T2 and hold them down for at least 5s
2
nd
Release T1 and T2
3
rd
Press button T1 three times
All the parameters can be adjusted as required without any contraindica-
tion; only the adjustment of the "motor force" requires special care:
• Do not use high force values to compensate for points of abnormal fric-
tion on the door. Excessive force can compromise the operation of the
safety system or damage the door.
• If the "motor force" control is used to assist the impact force reduc-
tion system, measure the force again after each adjustment in compliance
with EN standard 12445.
• The weather conditions may affect the movement of the door, therefore
periodic re-adjustments may be necessary.
TABLE 9
Action: operation to be performed at point 3 in the adjustment phase
Press button T1 once
Press button T1 twice
Press button T1 three times
Press button T1 four times
Press button T2 once
Press button T2 twice
Press button T2 three times
Press button T2 four times
Press button T3 once
Press button T3 twice
Press button T3 three times
Press button T3 four times
Press button T4 once
Press button T4 twice
Press button T4 three times
Press button T4 four times
Press button T5 once
Press button T5 twice
Press button T5 three times
Press button T5 four times
1 Press buttons T1 and T2 on the radio transmitter simultaneously
for at least 5s.
2 Release the two buttons.
3 Within 3 seconds, perform the action described in Table 10 based
T2