TECHNICAL CHARACTERISTICS OF THE VARIOUS COMPONENTS OF THE PRODUCT
The product AVIO600 / AVIO1000 is produced by Nice S.p.a. (TV) I. In order to improve its products, Nice S.p.a. reserves the right to modify their tech-
nical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: all the technical characteristics refer to a temperature of 20°C.
DESCRIPTION
Type
Adopted technology
Peak thrust [corresponds to the force
necessary to move a leaf]
Nominal torque [corresponds to the
force necessary to keep a leaf moving]
Idling speed
Speed at nominal torque
Maximum frequency of cycles
Maximum continuous cycle time
Operating Limits
Power supply AVIO
Max. absorbed power
Insulation class
Emergency power supply
Flashing light output
Courtesy light
BUS output
"OPEN" input
"SbS" input
"STOP" input
Radio aerial input
Maximum cable length
Remote control possibility
ECCO5... transmitters memorised
Range of ECCO5... transmitters
Programmable functions
Self-programmed functions
Operating ambient temperature
Assembly
Protection rating
Dimensions / weight
24 – English
AVIO600
Electromechanical gearmotor for automated sectional and overhead doors incorporating a control
unit complete with radio receiver for "ECCO5..." transmitters.
24V
motor, helical teeth reduction gear; drive guide with timing belt and mechanical release. A
transformer inside the motor but separated from the control unit reduces mains voltage to the nomi-
nal voltage of 24V
10,8 Nm
[600 N]
5,4 Nm
[300 N]
0,2 m/s
0,09 m/s
(For a maximum of approx. 10 cycles per hour. A maximum of 5 cycles per hour
Its structural characteristics make it suitable for use on sectional and overhead doors with counter-
weights that are within the dimensions and limits indicated in table 7
250 W
I (a safety grounding system is required)
For Led visual signalling devices (mod. FL200)
One output with a maximum load of 6 ECSbus units
For normally open contacts (the closing of the contact causes the "OPEN" command)
For normally open contacts (the closing of the contact causes the "Step-by-Step" command)
For normally open contacts and/or for 8,2kΩ constant resistance, or normally closed contacts with
recognition of the "normal" status (any variation from the memorised status causes the "STOP"
52 Ω for RG58 or similar type of cable
Mains power supply: 30 m; inputs/outputs: 20m with aerial cable preferably shorter than 5m
(observe the directions regarding the minimum gauge and type of cable)
With ECCO5... transmitters, the control unit can receive one or more of the following commands:
"Step-by-Step" (SbS), "Partial opening", "Open only" and "Close only"
Up to 100 if memorised in mode 1
From 10 to 50 m without aerial, from 50 to 100 m with aerial incorporated in the FL200 flashing
light. The range can vary if there are obstacles or electromagnetic disturbances, and is affected by
the position of the receiving aerial incorporated in the flashing light.
Pause time: selectable options 10, 20, 40, 80 seconds
Motor speed: 4 configurations available
Motor force: 4 configurations available
"Step-by-Step" (SbS) command: 4 configurations available
Exclusion position: 4 possible configurations 
Automatic detection of devices connected to the BUS Output.
Automatic detection of the type of "STOP" device (NO/NC contact, 8.2 kΩ resistor or OSE optical device)
Automatic detection of door length and calculation of deceleration points.
DATA
used by the automation system.
50 complete cycles per day
is permitted at 50°C
230 V
(±10%) 50/60 Hz
with PR100 accessory
Internal LED light
command)
-20°C...+55°C
Horizontal
IP40
380 x 280 x h 110 mm / 4 kg
AVIO1000
18 Nm
[1000 N]
9 Nm
[500 N]
0,2 m/s
0,09 m/s
370 W