Operating Instructions SATAjet 1800 M
Attention!
Damage from incorrect cleaning
There is a risk of corrosion if the automatic gun is submerged in the
cleaning solution.
→ Never submerge the automatic gun in cleaning solution.
■ Clean the automatic gun every time after it has been used and every
time before changing the material.
13. Malfunctions
If it is not possible to remedy a malfunction with the described corrective
actions, send the automatic gun to the SATA customer service department
(address see chapter 15).
Malfunction
Fluttering spray fan
pattern
Cause
Fluid tip not tightened
properly.
Air distribution ring
soiled or damaged.
Loose air cap.
Gap between air
cap and fluid tip is
clogged.
Nozzle set is soiled.
Nozzle set damaged
or worn
Material flow pressure
not constant.
Corrective action
Tighten fluid tip hand-
tight.
Replace air distribution
ring (see chapter 10.2).
Tighten air cap ring
handtight, ensuring the
grooves are aligned to
the tapered dowel pin.
Clean gap.
Replace air distribution
ring.
Clean nozzle set.
Replacing the nozzle
set
(see chapter 10.1)
Check material flow
pressure, possibly
adjust higher material
pre-pressure.
Remove soiling in ma-
terial system.
EN