Malfunctions; Corrective Action - SATA SATAjet 3000 K RP Mode D'emploi

Masquer les pouces Voir aussi pour SATAjet 3000 K RP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating Instructions SATAjet 3000 K (RP/HVLP)
EN
Note!
In rare cases, it may be necessary to dismantle some parts of the spray
gun to clean them thoroughly. If dismantling should be necessary, this
should be limited just to the parts whose function brings them in contact
with the material.
■ Purge spray gun thoroughly with thinner.
■ Clean air cap with a paint brush or brush.
■ Lightly grease moving parts with high performance grease.

11. Malfunctions

The malfunctions described below may only be remedied by trained per-
sonnel.
If it is not possible to remedy a malfunction with the described corrective
actions, send the spray gun to the SATA customer service department
(address see chapter 16).
Malfunction
Jerky spray fan pat-
tern (wobbling/splut-
tering) or air bubbles
in suction cup.
Spray pattern too
small, slanted,
one-sided or split.
Round / flat fan control
not working – control
can be regulated.
126
Cause
Fluid tip not tightened. Tighten fluid tip with
Air distribution ring
damaged or clogged.
Air cap holes clogged
with paint.
Damaged fluid tip
(fluid tip aperture).
Air distribution ring not
correctly positioned
(pin not in hole) or
damaged.
Not enough material in
suction cup.

Corrective Action

universal spanner.
Replace air distribution
ring (see chapter 9.2).
Clean air cap. Heed
cleaning instructions
(see chapter 10).
Check fluid tip for dam-
age and replace nozzle
set if necessary (see
chapter 9.1).
Replace air distribution
ring (see chapter 9.2).
Fill suction cup (see
chapter 8.2).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Satajet 3000 k hvlp

Table des Matières