Damage from wrong cleaning agents
The spray gun can be damaged by using aggressive cleaning agents to
clean it.
→ Do not use aggressive cleaning agents.
→ Use neutral cleaning agents with a pH of 6 – 8.
→ Do not use acids, caustic solutions, bases, paint strippers, unsuitable
regenerates or other aggressive cleaning agents.
Physical damage from incorrect cleaning
The spray gun can be damaged if immersed in solvent or cleaning agent
or if cleaned in an ultrasonic cleaning machine.
→ Do not place the spray gun in solvent or cleaning agent.
→ Do not clean the spray gun in an ultrasonic cleaning machine.
Damage from incorrect cleaning tool
Never use unsuitable objects to clean clogged holes. Even the tiniest
damage can influence the spray pattern.
→ Use SATA nozzle cleaning needles (# 62174) or (# 9894).
In rare cases, it may be necessary to dismantle some parts of the spray
gun to clean them thoroughly. This should only be limited to parts in
contact with the coating material during use.
■ Purge spray gun thoroughly with cleaning agent.
■ Clean air cap with a paint brush or brush.
■ Lightly grease moving parts with high performance grease.

12. Malfunctions

The malfunctions described below may only be remedied by trained per-
sonnel.
If it is not possible to remedy a malfunction with the described corrective
actions, contact your SATA dealer (address see chapter 15).