Notice!
In rare cases, it may be necessary to dismantle some parts of the spray
gun to clean them thoroughly. If dismantling should be necessary, this
should be limited just to the parts whose function brings them in contact
with the material.
■ Purge spray gun thoroughly with thinner.
■ Clean air cap with a paint brush or brush.
■ Lightly grease moving parts with high performance grease.

12. Malfunctions

The malfunctions described below may only be remedied by trained per-
sonnel.
If it is not possible to remedy a malfunction with the described corrective
actions, send the spray gun to the SATA customer service department
(address see chapter 17).
Malfunction
Jerky spray fan pat-
tern (wobbling / splut-
tering) or air bubbles
in the gravity flow cup.
Air bubbles in gravity
flow cup.
Cause
Fluid tip not tightened. Tighten fluid tip with
Air distribution ring
damaged or clogged.
Loose air cap.
Gap between air cap
and fluid tip (air circuit)
is clogged.
Nozzle set is soiled.
Damaged nozzle set.
Not enough material in
gravity flow cup.
Defective paint needle
seal.

Corrective action

universal spanner.
Replace air distribution
ring (see chapter 10.2).
Tighten the air cap
hand-tight.
Clean air circuit. Heed
cleaning instructions
(see chapter 11).
Clean nozzle set. Heed
cleaning instructions
(see chapter 11).
Replace nozzle set (see
chapter 10.1).
Fill gravity flow cup (see
chapter 9.2).
Replace paint needle
seal (see chapter 10.3).