■ Press the air distribution ring in evenly.
■ Mount nozzle set (see chapter 10.1).
After installation, adjust the material flow according to chapter 9.2.
10.3. Replace paint needle seal
This must be replaced when material leaks from the self-adjusting paint
needle packing.
Dismantle paint needle seal
■ Loosen locknut [1-4].
■ Screw adjusting screw [1-3] with counter nut out of the gun body.
■ Remove spring and paint needle [9-1].
■ Remove the trigger guard [9-2].
■ Screw the paint needle seal [9-3] out of the gun body.
Mount paint needle seal
■ Screw the paint needle seal [9-3] into the gun body.
■ Mount the trigger guard [9-2].
■ Insert spring and paint needle [9-1].
■ Screw adjusting screw [1-3] into spray gun body with locknut [1-4].
After installation, adjust the material flow according to chapter 9.2.
10.4. Replace air piston, air piston spring and air microme-
ter
Risk of injuries from air micrometer coming loose.
When the locking screw is not screwed tight, the air micrometer can
shoot uncontrolled out of the spray gun.
→ Check that the locking screw of the air micrometer fits firmly and
tighten if necessary.
Replacement is necessary if
air escapes at the air cap or air micrometer without actuating the trigger
guard.
Dismantle air piston, air piston spring and air micrometer
■ Screw the locking screw [10-1] out of the gun body.
■ Pull the air micrometer [10-4] out of the gun body.
■ Remove the air piston with air piston spring [10-5].
■ Remove the air piston rod [10-3].
Mount air piston, air piston spring and air micrometer
■ Insert the air piston rod [10-3] in the correct position.