Operating Instructions SATAjet 3000 K (RP/HVLP)
Malfunction
Round / flat fan control
cannot be regulated.
Spray gun does not
shut air off.
Corrosion on air
cap thread, material
passages (cup con-
nection) or spray gun
body.
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at flu-
id tip ("fluid tip cone").

12. Disposal

Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!
Cause
Round / flat fan control
has been turned coun-
terclockwise over the
limit; spindle loose in
gun thread.
Air piston seat
clogged.
Air piston worn.
Cleaning solution (wa-
tery) remains in the
gun for too long.
Unsuitable cleaning
solutions used.
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective Action
Unscrew round / flat
fan control using the
universal spanner and
make it work again or
replace it completely
(see chapter 9.6).
Clean air piston seat.
Heed cleaning instruc-
tions (see chapter 10).
Replace air piston and
air piston packing (see
chapter 9.4).
Have gun body re-
placed. Heed cleaning
instructions (see chap-
ter 10).
Replace paint needle
seal (see chapter 9.3).
Replace nozzle set (see
chapter 9.1).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.1).
EN
127

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Satajet 3000 k hvlp

Table des Matières