Operating Instructions SATA spray master RP
Malfunction
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at
fluid tip ("fluid tip aper-
ture").
12. Disposal
Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!
13. After Sales Service
For accessories, spare parts and technical support, contact your SATA
dealer.
14. Accessories
Art. No.
Description
6981
Quick coupling nipple G1/4 IG
64030
SATA cleaning set
9902
Air hose
48173
High performance grease
10009
High performance grease
Cause
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective action
Replace paint needle
seal.
Replace nozzle set (see
chapter 9.2).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 10).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 10).
Replace nozzle set (see
chapter 9.2).
Num-
ber
5 ea.
1 set
1 ea.
1 ea.
6 units
EN