Operating Instructions SATA spray master RP
End the spraying process
■ Bring the trigger guard [1-12] to the starting position.
■ At the end of the spraying process, interrupt the spraying air and empty
the gravity flow cup [1-14]. Comply with the instructions for care and
storage (see chapter 10).

9. Maintenance and repairs

Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
The following chapter describes the procedures involved for maintaining
and repairing the
spray gun. Maintenance and repair work may only be
carried out by trained skilled workers.
■ Always interrupt the compressed air supply to the compressed air con-
nection [1-9] before performing any maintenance and repair work.
Spare parts are available for carrying out repairs (see chapter 15).
9.1. Replace trigger guard
Remove trigger guard
■ Loosen counter nut of adjusting screw [1-4].
■ Screw adjusting screw with counter nut out of gun body.
■ Remove spring and paint needle.
■ Carefully remove circlips.
■ Pull both bolts out.
■ Remove trigger guard.
Mount trigger guard
Warning!