Operating Instructions SATA spray master RP
8.2. Normal Operation
Connect spray gun
■ Connect compressed air hose to air connection [1-9].
Fill with material
Notice!
When painting, only use as much material as is required for the specific
procedure.
When painting, maintain the necessary spray distance. After painting,
store or dispose of the material correctly.
■ Unscrew screw-on lid [1-15] from gravity flow cup [1-14].
■ Remove drip-stop [# 70664].
■ Fill gravity flow cup (maximum 20 mm below top edge).
■ Insert drip-stop.
■ Screw the screw-on lid onto the gravity flow cup.
Adjust material pressure
The material pressure can be read off at the pressure gauge [1-8] with
subsequent fully various adjustment at the control knob [1-10].
■ Pull control knob [1-10] away from spray gun until it audibly releases.
■ Adjust spraying air quantity at the control knob and read off spray fan
pressure at the pressure gauge.
■ Press control knob towards spray gun until it audibly engages.
■ Open bleeder valve [1-2] briefly and check whether the pressure gauge
adjusts back to the required pressure again.
Adjust gun inner pressure
Notice!
When using an external pressure regulator to adjust the gun inner pres-
sure, the air micrometer [# 53603] must be wide open (vertical posi-
tion).
Notice!
The most precise way to adjust the gun inner pressure is with SATA
adam 2.
EN
117