Maintenance And Repairs - SATA SATAjet 3000 K RP Mode D'emploi

Masquer les pouces Voir aussi pour SATAjet 3000 K RP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating Instructions SATAjet 3000 K (RP/HVLP)
Start spraying process
■ Observe correct spray distance (see chapter 7).
■ Pull trigger guard right back [6-2] and hold spray gun at 90° to the
surface being sprayed [6-1].
■ Ensure there is sufficient spraying air feed and material supply.
■ Pull trigger guard [1-10] back and start spraying process. Adjust mate-
rial flow and spray fan pattern if necessary.
End the spraying process
■ Bring the trigger guard [1-10] to the starting position.
■ When the spraying process finishes, interrupt the spraying air. Comply
with the instructions for care and storage (see chapter 10).

9. Maintenance and repairs

Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
→ Always use the SATA extraction tool pointing away from your body.
The following chapter describes the procedures involved for maintaining
and repairing the
spray gun. Maintenance and repair work may only be
carried out by trained skilled workers.
■ Always interrupt the compressed air supply to the compressed air con-
nection [1-7] before performing any maintenance and repair work.
Spare parts are available for carrying out repairs (see chapter 15).
Warning!
Warning!
EN
121

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Satajet 3000 k hvlp

Table des Matières