Maintenance And Repairs - SATA jet 1000 B Mode D'emploi

Masquer les pouces Voir aussi pour jet 1000 B:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating Instructions SATAjet 1000 B (RP/HVLP)
8.

Maintenance and repairs

Risk of injuries from components coming loose or leaking
material.
If maintenance work is performed while still connected to the com-
pressed air circuit, components can unexpectedly work loose and mate-
rial can leak.
→ Always disconnect the spray gun from the compressed air circuit
before performing any maintenance work.
Risk of injury from sharp edges
There is a risk of injury from sharp edges when fitting the nozzle set.
→ Wear protective gloves.
→ Always use the SATA extraction tool pointing away from your body.
The following chapter describes the procedures involved for maintaining
and repairing the
spray gun. Maintenance and repair work may only be
carried out by trained skilled workers.
■ Always interrupt the compressed air supply to the compressed air con-
nection [1-8] before performing any maintenance and repair work.
Spare parts are available for carrying out repairs (see chapter 14).
8.1. Replace nozzle set
Damage from incorrect installation
The fluid tip and paint needle can be damaged if assembled in the
wrong order.
→ Always comply with the assembly sequence. Never screw the fluid tip
against an energised paint needle.
The nozzle set consists of a tested combination of air cap [7-1], fluid tip
[7-2] and paint needle [7-3]. Always replace the complete nozzle set.
Dismantle the nozzle set
■ Loosen counter nut [1-4].
■ Screw adjusting screw [1-3] with counter nut out of the gun body.