Operating Instructions SATAjet 1000 B (RP/HVLP)
EN
Adjust the material flow
Notice!
Wear at the fluid tip and paint needle is lowest when the material flow
control is wide open. Select fluid tip size according to the material and
working speed.
Fully variable adjustment of the material flow and thus the needle stroke
is possible with the adjusting screw as shown in Figs. [4-1], [4-2], [4-3]
and [4-4].
■ Loosen counter nut [1-4].
■ Pull trigger guard [1-11] right back.
■ Adjust material flow at the adjusting screw [1-3].
■ Tighten counter nut by hand.
Adjust spray fan pattern
Fully variable adjustment of the spray fan pattern is possible using the
round / flat fan control [1-2] to achieve a round fan.
■ Adjust the spray fan pattern by regulating the round and flat fan control
[1-2].
■ Turn to the right [5-2] – for a round fan
■ Turn to the left [5-1] – for a flat fan
Start spraying process
■ Observe correct spray distance (see chapter 2).
■ Pull trigger guard right back [6-2] and hold spray gun at 90° to the
surface being sprayed [6-1].
■ Ensure there is sufficient spraying air feed and material supply.
■ Pull trigger guard [1-11] back and start spraying process. Adjust mate-
rial flow and spray fan pattern if necessary.
End the spraying process
■ Bring the trigger guard [1-11] to the starting position.
■ At the end of the spraying process, interrupt the spraying air and empty
the gravity flow cup [1-16]. Comply with the instructions for care and
storage (see chapter 9).