Operating Instructions SATAjet 3000 K (RP/HVLP)
■ Operating Instructions
After unpacking, check:
■ Spray gun damaged
■ Complete scope of supply

6. Technical Design

6.1. Spray gun

[1-1]
Round / flat fan control
[1-2]
Material flow control
[1-3]
Counter nut material flow
control
Air micrometer (aif flow
[1-4]
control knob)
Air micrometer (air flow
[1-5]
control) locking screw
[1-6]
Air piston (not visible)
6.2. Air micrometer (aif flow control knob)
[3-1]
SATA adam 2 (see
chapter 14)
[3-2]
Separate pressure gauge
with control device (see
chapter 14)

7. Technical Data

Gun inlet pressure
recommended
RP
recommended
HVLP
Compliant
Compliant legisla-
tion Lombardy / It-
aly
Max. gun input pressure (air)
Max. gun input pressure (material)
[1-7]
Compressed air connection
G ¼ „ (male thread)
[1-8]
ColorCode-System (CCS)
Spray gun handle
[1-9]
[1-10] Trigger
[1-11] Material connection G⅜ „
(male thread)
[1-12] Nozzle set consisting of air
cap, fluid tip (not visible),
paint needle (not visible)
[3-3]
Separate pressure gauge
without control device (see
chapter 14)
Pressure measurement in
[3-4]
compressed air circuit
2.5 bar
2.5 bar
> 2.5 bar (air cap
pressure > 0.7 bar)
< 3.0 bar (air cap
pressure < 1.0 bar)
10.0 bar
35 psi
35 psi
> 35 psi (air cap
pressure > 10 psi)
< 44 psi (air cap
pressure < 15 psi)
145 psi
EN
117