DC Output Specifications
DC Output Specifications
AC 6012 Battery
Charger
Nominal
12 VDC
battery voltage
Normal
0 – 16 VDC
operating
output range
Maximum DC
60 +10% A
output current
(total)
Absorption voltage @ 77 °F (25 °C)
Flooded
14.0 ±0.1
GEL
14.2 ±0.1
AGM
14.4 ±0.1
Odyssey
14.7 ±0.1
LFP
14.6
Float voltage @ 77 °F (25 °C)
Flooded
13.5 ±0.1
GEL
13.8 ±0.1
AGM
13.4 ±0.1
Odyssey
13.5 ±0.1
LFP
13.4
Equalize mode
10A
current
74
AC 4012 Battery
Charger
12 VDC
0 – 16 VDC
40 +10% A
14.0 ±0.1
14.2 ±0.1
14.4 ±0.1
14.7 ±0.1
14.6
13.5 ±0.1
13.8 ±0.1
13.4 ±0.1
13.5 ±0.1
13.4
10A
DC Output Specifications
AC 6012 Battery
Charger
Equalize
16 ±0.1 VDC
mode—
maximum
output voltage
Off-state
<35 mA DC
current draw
(without
remote
installed)
Voltage
Uncompensated load voltage
regulation
regulation
< 0.1 VDC drop from 0 Amps
to rated current output at
charger output terminals
(adds in series with
recommended 3% limit for
user's battery cable voltage
drop).
DC Aux output
12 VDC in conjunction with
voltage
BAT1
DC Aux output
20 A
current
Kussmaul Chief Auto Charge Battery Charger Owner's Guide
AC 4012 Battery
Charger
16 ±0.1 VDC
<35 mA DC
Uncompensated load voltage
regulation
< 0.1 VDC drop from 0 Amps
to rated current output at
charger output terminals
(adds in series with
recommended 3% limit for
user's battery cable voltage
drop).
12 VDC in conjunction with
BAT1
20 A