Symptom
The Auto Charge appears to be taking too long to charge battery.
Ready indicator LED does not illuminate after 24 hours of
charging.
Possible Cause
Battery capacity is too high
for the Auto Charge model.
Load connected to battery is
draining charge current so
that battery does not
recharge.
Battery has a damaged cell
or has reached the end of
its useful life.
The remote panel Max
Output setting is too low for
the battery capacity.
975-1023-01-01
Solution
Use a higher capacity charger.
Disconnect all loads or switch
loads off.
Replace battery.
Increase the Max Output setting.
Symptom
The Auto Charge appears to have quickly charged the battery.
Ready indicator LED illuminates sooner than expected.
Possible Cause
Battery capacity is too low
for the Auto Charge model.
Battery has a damaged cell
or has reached the end of
its useful life.
Troubleshooting
Solution
Reduce the Maximum Charge
Current setting.
Replace battery.