Télécharger Imprimer la page

Ac Input Specifications; Dc Output Specifications - Kussmaul Electronics Kussmaul Chief Auto Charge Guide D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

AC Input Specifications

AC input voltage range
Nominal:
Full:
Automatic derating to 80% output:
Max. AC input current
Power factor at rated load
Frequency
Efficiency – peak
Surge protection
975-1023-01-01
AC 6012
AC 4012
Battery
Battery
Charger
Charger
110 | 120 | 230 | 240 VAC
80 – 255  VAC
255 – 270 VAC
9 A
5.7 A
≥0.98
≥0.98
45 – 65 Hz
45 – 65 Hz
89% @ 120  VAC
89% @ 120  VAC
Line-to-neutral
Line-to-neutral
surge protector
surge protector
rated at
rated at
275 VAC
275 VAC

DC Output Specifications

AC 6012 Battery
Charger
a
Battery types
Flooded, GEL, AGM, Odyssey,
LFP (lithium iron phosphate)
Battery bank
600 Ah
b
size
Number of
3 separated outputs
isolated
battery bank
outputs
DC (battery)
0 – 16  VDC
output voltage
range
including dead
battery
charging
voltage
Maximum
16  VDC
equalization
voltage
Voltage
14.4 ±0.1 VDC
accuracy (no
@ 77 °F (25 °C)
load)
a
Do not mix battery types. Refer to battery manufacturer specifications for correct battery type.
b
Recommended battery bank sizes are tested by the Department of Energy (DOE). Larger and smaller
size batteries could be charged as well, but their use are not automatically verified by DOE.
AC Input Specifications
AC 4012 Battery
Charger
Flooded, GEL, AGM, Odyssey,
LFP (lithium iron phosphate)
400 Ah
3 separated outputs
0 – 16  VDC
16  VDC
14.4 ±0.1 VDC
@ 77 °F (25 °C)
73

Publicité

Chapitres

loading