Troubleshooting
Symptom
The Auto Charge will not perform equalization.
Possible Cause
Battery is the wrong type, or
set to the wrong type to
equalize.
Not all batteries are fully
charged.
An active fault is present on
the bank you are attempting
to equalize.
70
Solution
Determine if the battery type is set
to GEL or AGM. These battery
types cannot be equalized.
The charger will wait for all
batteries to be in float stage of
three-stage charging or rest stage
of two-stage charging before
attempting to equalize (the ready
indicator LED will illuminate).
Clear the active fault by
disconnecting the AC power
source and finding the cause of
the fault from  Interpreting Alert
Indicators on page 59.