STANDARD TEST ________________________________________________________________________ STARGAS
Possible causes for CO - CO
CO
HC
CO
2
O
2
36
- HC and O
2
Wrong carburation adjustment
Dirty or obstructed air filter
Defective enrichment of the heating phase
Defective enrichment of the acceleration
Defective spark plugs
Defective pressure regulator
IGNITION LEAKAGES:
Defective reducer contacts
Defective spark plug cables
Wrong advance
Defective spark plugs
INCOMPLETE COMBUSTION:
Lean mixture
Defective suction circuit tightness
MECHANICAL DEFECTS:
Insufficient compression
Valves that are not tight
Exhaust system tightness
Exhaust system tightness
Rich mixture
Defective Lambda Probe
wrong values
2