How To Connect The Stargas - tecnotest STARGAS Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTION _________________________________________________________________________ STARGAS
2.0 -

HOW TO CONNECT THE STARGAS

To connect the STARGAS:
Remove the tool form the package and place it in the special trolley
housing (option).
The package should be kept in case that you need it again
subsequently to transport the analyser.
ATTENTION:
Remove the protection plugs which have been
inserted in the external connections.
It is necessary to keep the plugs because in
case that a new package is needed for the
forwarding to the laboratory
overhaul, repair), they assure a suitable
protection to the whole internal pneumatic
circuit.
Insert the pipe (65) in the condensate outlet connection (50) so as to
convey the condensate far from the analyser.
Set up the gas pick-up system according to the following rules:
Insert the sampling gas probe (71) in the 6 m piping (64-b).
Connect to the piping the external precleaner which is equipped with
its 80 cm pipe (64-a).
Insert the above-mentioned assemblage into the inlet gas connection
(51).
Connect the RPM battery cable (80) to the RPM socket (37).
Connect the ground cable (78) to the
Connect the temperature probe (79) to the TEMP. °C tap (38).
Connect the extension (76) to the
the Lambda probe/central unit.
Attach to the extension (76) the SHUNT cable (74) or the connecting
cable of the test prod clamp (73) with the prod (75).
Connect the sample gas bottle if required by the rules in force to the
coupler (52).
14
(calibration,
COM port (41).
λ
tap (40) to check the effectiveness of
OPERATING INSTRUCTIONS

Publicité

Table des Matières
loading

Table des Matières