OCP<n> <nrf>
Set output <n> over current protection trip point to <nrf> Amps
V<n>?
Return the set voltage of output <n> . For AUX output <n>=3
– response is V <n> <nr2><rmt> where <nr2> is in Volts
I<n>?
Return the set current limit of output <n>
– response is I <n> <nr2><rmt> where <nr2> is in Amps
OVP<n>?
Return the voltage trip setting for output <n>
– response is VP<n> <nr2><rmt> where <nr2> is in Volts
OCP<n>?
Return the current trip setting for output <n>
– response is IP<n> <nr2><rmt> where <nr2> is in Amps
V<n>O?
Return the output readback voltage for output <n>. For AUX output <n>=3
– response is <nr2>V<rmt> where <nr2> is in Volts
I<n>O?
Return the output readback current for output <n>. For AUX output <n>=3
RANGE<n> <nrf>
Set the voltage range of output <n> to <nrf> where <nrf> has the following
meaning:
XDL 35-5 Models: 0=15V(5A), 1=35V(3A), 2=35V(500mA)
XDL 56-4 Models: 0=25V(4A), 1=56V(2A), 2=56V(500mA)
RANGE<n>?
Return the set voltage range of output <n>
– response is R<n> <nr1><rmt> where <nr1> has the following meaning:
XDL 35-5 Models: 0=15V(5A), 1=35V(3A), 2=35V(500mA)
XDL 56-4 Models: 0=25V(4A), 1=56V(2A), 2=56V(500mA)
DELTAV<n> <nrf> Set the output <n> voltage step size to <nrf> Volts. For AUX output <n>=3
DELTAI<n> <nrf>
Set the output <n> current step size to <nrf> Amps
DELTAV<n>?
Return the output <n> voltage step size. For AUX output <n>=3
– response is DELTAV<n> <nr2><rmt> where <nr2> is in Volts.
DELTAI<n>?
Return the output <n> current step size
– response is DELTAI<n> <nr2><rmt> where <nr2> is in Amps.
INCV<n>
Increment the output <n> voltage by the step size set for output <n>.
For AUX output <n>=3
INCV<n>V
Increment with verify the output <n> voltage by the step size set for output <n>.
For AUX output <n>=3
DECV<n>
Decrement the output <n> voltage by the step size set for output <n>.
For AUX output <n>=3
DECV<n>V
Decrement with verify the output <n> voltage by the step size set for output
<n>. For AUX output <n>=3
INCI<n>
Increment the output <n> current limit by the step size set for output <n>
DECI<n>
Decrement the output <n> current limit by the step size set for output <n>
OP<n> <nrf>
Set output <n> on/off where <nrf> has the following meaning: 0=OFF, 1=ON
For AUX output <n>=3
OP<n>?
Returns output <n> on/off status. For AUX output <n>=3
The response is <nr1><rmt> where 1 = ON, 0 = OFF.
Simultaneously sets all outputs on/off where <nrf> has the following meaning:
OPALL <nrf>
0=All OFF, 1=ALL ON.
If OPALL sets all outputs ON then any that were already on will remain ON.
If OPALL sets all outputs OFF then any that were already off will remain OFF
– response is <nr2>A<rmt> where <nr2> is in Amps