WS 170 bypass unit
A
WS 170 ventilation unit
A1
Electronic slide-in module
A2
Control circuit board
A3
Frost protection heating register
A4
Bypass shutter
B
RLS D1 WR room air control
W1
230 V AC connection cable
W2
Shielded control cable provided by
customer, e.g. LiYCY 2 x 0.75 mm²
for RLS D1 WR room air control
Instead of B1 (RLS 1 WR) room air
control, B (RLS D1 WR) room air
control can be connected.
W2´
Control cable (provided by customer)
for RLS 1 WR room air control
Outer diameter of control cable
3.2...6.5 mm, e.g. LIYY 6x0.34 mm²
S1
Unit switch
GW1
Gateway frost protection heating
register
GW2
Gateway bypass shutter
M1
Supply air fan
M2
Exhaust fan
S
Door contact switch: Activated by
front plate
T-min
Frost protection temperature sensor
T-AUL
Outside air temperature sensor
Supply air
Z1 (blue) Potentiometer adjuster
Ventilation level 1
Z2 (blue) Potentiometer adjuster
Ventilation level 2
Z3 (blue) Potentiometer adjuster
Ventilation level 3
Exhaust air
A1 (red) Potentiometer adjuster
Ventilation level 1
A2 (red) Potentiometer adjuster
Ventilation level 2
A3 (red) Potentiometer adjuster
Ventilation level 3
12. Appendix ‒ Wiring diagram for WS 170 bypass unit │ uk
Jumper settings (Chapter 6.7.3)
J 1-3
Unit type, 000 = WS 170
J 4-5
Frost protection temp. (Chap. 6.7.4)
J 6
No function
J 7
Jumper 7 open: Ventilation level 3 is
reset after an hour.
J 8
RLS 1 WR or RLS D1 WR room air
control active: Leave factory setting,
J8 must be bridged.
J 9
Jumper 9 open: The ventilation unit
can be switched off at the room air
control. Jumper 9 bridged:
RLS 1 WR: Switch-off function blocked
RLS D1 WR: Ventilation unit runs in
"Humidity protection ventilation"
ventilation level in the OFF switch
position.
J10
HY 5 or CO
sensor, jumper 10 must be open.
Jumper 10 open: Hygrostat released
with potential-free contact.
Jumper 10 bridged: CO
(0 to 10 V output) released.
Further connection options
W3
Connection cable (provided by custo-
mer) for external operating display.
k1
Potential-free relay contact (max.
3 A / 250 V AC, 2 A / 30 V DC).
The contact is closed when the
ventilation unit is running.
Connection cable (provided by cus-
W4
tomer) for external CO
sensor or external hygrostat (with
potential-free contact).
W5
Connection cable (provided by
customer) for external differential
pressure controller.
Differential pressure controller with
potential-free relay contact. Minimum
switching power of relay contact:
230 V AC/2 A. Remove J1 bridge on
A2 control circuit board.
W6
Connection cable (provided by
customer) for external differential
pressure controller.
Sensor type=NTC 10k. Remove
resistor 12k on GW1 circuit board.
/VOC sensor: Without a
2
/ VOC
2
or VOC
2
77