Lenses with reverse polarity motors: Implement
the connections, as shown in the figure..
+
M
+
M
+
M
Fig. 17
CN2.
Lenses with common wire motors: Implement the
connections, as shown in the figure..
+
M
+
M
+
M
Fig. 18
CN2.
Potentiometers: Implement the connections, as
shown in the figure..
Fig. 19
CN3.
18
FOCUS +
FOCUS -
IRIS +
IRIS -
ZOOM +
ZOOM -
CN2
FOCUS +
FOCUS -
IRIS +
IRIS -
ZOOM +
ZOOM -
CN2
+ POT
FOCUS
IRIS
ZOOM
- POT
GND
CN3
Camera: Implement the connections, as shown in
the figure..
Serial
Power supply
Day/Night synchroni-
sation
Fig. 20
Refer to the relative chapter to enable camera control
(10.1.6 Housing Serial Port Menu, page 45).
7.4.2 Adjustment of the supply voltage
of the lens motors
Before powering the Pan & Tilt, select the lens power
voltage using DIP1 (7.4 Housing board description,
page 17).

ADJUSTMENT OF THE SUPPLY VOLTAGE OF THE LENS MOTORS

SW1
SW2
Voltage
OFF
OFF
15Vdc
ON
OFF
12Vdc
OFF
ON
9Vdc
ON
ON
6Vdc
Tab. 3
232 TX
232 RX
GND
485_B
485_A
S_GND
CN6
Video
CN1
+ 12V
GND
F1
F2
MNVCUPTMAXB_1511_EN