Videotec ULISSE MAXI Manuel D'instructions page 62

Masquer les pouces Voir aussi pour ULISSE MAXI:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 146
PROBLEM
A display such as that shown below
appears instead of the footage:
INFO
------------------------
Device ID: 00001
Type
: Rs485 only Rx
Baud Rate: 19200-8N1
Protocol : PELCO-D
Net Board: Fw05.01 Hw00
Mpp Board: Fw05.01 Hw00
Config.
: 001
P.C.
: UPT1SMSA005C
S.N.
: 0000000000000
Upgrade
: NET BOARD
CAUSE
Programming dip-switch on.
SOLUTION
Turn off the P&T. Lower the firmware
update dip-switch lever (8.14.2 DIP1
configuration, page 34). Turn the unit
on again.
PROBLEM
Error E1:PATROL CONFIGURATION.
CAUSE
The presets have not been saved.
The presets have not been enabled.
SOLUTION
Save one or more presets (12.2 Saving
a Preset, page 54). Update the Patrol
configuration menu (10.1.8.6 Patrol
Menu, page 48).
Enable presets (10.1.8.4 Preset Menu
(Edit Preset), page 47).
60
PROBLEM
Error E2:AUTOPAN
CONFIGURATION.
CAUSE
The two presets used as limits have
not been saved.
The two presets used as limits have
not been enabled.
SOLUTION
Save two presets (12.2 Saving a
Preset, page 54). Update the autopan
configuration menu (10.1.8.7 Autopan
Menu, page 48).
Enable presets (10.1.8.4 Preset Menu
(Edit Preset), page 47).
PROBLEM
Error E3:WASHER DISABLED or error
E4:WASHER PRST DISABLED.
CAUSE
Washing system not enabled.
SOLUTION
Enable the washer system (10.1.10.3
Washer Menu, page 51).
PROBLEM
Error PRESET XXX NOT ENABLED.
CAUSE
Restore an unsaved preset
Restore a non-enabled preset
SOLUTION
Save the preset using the relative
control (12.2 Saving a Preset, page 54).
Enable preset (10.1.8.4 Preset Menu
(Edit Preset), page 47).
MNVCUPTMAXB_1511_EN

Publicité

Table des Matières
loading

Table des Matières